| Specifications
Fluid Types:
Water based fluids compatible with Brass, PTFE and NBR rubber.
Connections:
See diagram below.
Note: Outputs are factory selectable and dual outputs on output 1 are available on request.
Vibration (15.3 grms)
3 orthoganol planes for 3 hours per plane
Frequency (Hz)
24
60
100
240
2000
|
G2/Hz
0.04
0.5
0.5
0.1
0.1
|
Test performed in accordance with BSEN 60068-2-64 : 1993
Electical Rating:
Supply Voltage:
Supply Current:
Max. Load Current:
Alarm Delay Time:
Connection:
Start up Delay:
|
5 VDC or 7 – 35 VDC
1.5mA + source output
1.0A (sink) or 20mA (source)
0 – 25 secs rising or falling (factory set)
4 way Delphi Packard connector
1 – 5 secs
|
Construction:
Body:
Probe:
Terminals:
Seals:
Connector:
Thread sealant:
|
Brass
PTFE
SAE CA210Brass, Tin Plated
NBR rubber
30% Glass Filled Nylon 6
Polyacrylate Aqueous Emulsion Base (Dri-Seal 5061) – 1/4″ NPT only
|
Environmental Ratings:
Sealing:
Max. pressure:
Temp. ranges:
Weight:
|
IP67
5.0 Bar (72 psi)
Fluid: -40°C to +130°C
Storage: -50°C to +140°C
53g
|
Note: Torque setting on installation should not exceed 22Nm. Unit should be tightened with a 31mm ring spanner or 31mm socket.
Optional accessory:
Mating connector kit to suit harness wire cross sectional area of 0.8 to 1.0mm² and sleeve Ø1.60 to 2.15mm:
Description:
Connector kit comprising of:
Crimp Terminals (x4)
Cable seals (x4)
Cavity plug (x1)
Connector assembly 4 way (x1)
TPA lock (x1)
From the Packard Metri-Pack 150 series of connectors.

|